40 CFR § 466.15
Pretreatment standards for new sources
June 9, 2020
Except as provided in 40 CFR 403.7 and 403.13, any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
Subpart A—PSNS
Open Table
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | ||
---|---|---|---|---|
Metal preparation | Coating operation | Metal prepartion | Coating operation | |
Metric units—mg/m2 of area processed or coated | ||||
Chromium | 3.7 | 0.47 | 1.5 | 0.19 |
Lead | 1.0 | 0.13 | 0.9 | 0.11 |
Nickel | 12.0 | 1.51 | 6.3 | 0.79 |
Zinc | 10.2 | 1.29 | 4.2 | 0.53 |
English units—pounds per 1 million ft2 of area processed or coated | ||||
Chromium | 0.76 | 0.10 | 0.31 | 0.04 |
Lead | 0.2 | 0.03 | 0.19 | 0.002 |
Nickel | 2.46 | 0.31 | 1.29 | 0.16 |
Zinc | 2.09 | 0.27 | 0.86 | 0.11 |
[47 FR 53184, Nov. 24, 1982, as amended at 50 FR 36543, Sept. 6, 1985]