40 CFR § 466.45
Pretreatment standards for new sources
June 9, 2020
Any new source subject to this subpart which introduces pollutants into a publicly owned treatment works must comply with 40 CFR part 403 and achieve the following pretreatment standards for new sources:
Subpart D—PSNS
Open Table
Pollutant or pollutant property | Maximum for any 1 day | Maximum for monthly average | ||
---|---|---|---|---|
Metal preparation | Coating operation | Metal preparation | Coating operation | |
Metric units—mg/m2 of area processed or coated | ||||
Chromium | 6.23 | 0.46 | 2.52 | 0.19 |
Lead | 1.69 | 0.13 | 1.52 | 0.11 |
Nickel | 9.25 | 0.69 | 6.23 | 0.47 |
Zinc | 17.16 | 1.29 | 7.07 | 0.53 |
English units—pounds per 1 million ft2 of area processed or coated | ||||
Chromium | 1.28 | 0.10 | 0.52 | 0.04 |
Lead | 0.35 | 0.03 | 0.31 | 0.02 |
Nickel | 1.90 | 0.14 | 1.28 | 0.10 |
Zinc | 3.52 | 0.27 | 1.45 | 0.11 |
[47 FR 53184, Nov. 24, 1982, as amended at 50 FR 36545, Sept. 6, 1985]