As required in §63.8010, you must meet each emission limit in the following table that applies to your storage tanks.

Open Table
For each .  .  . Then you must .  .  .
1. Group 1a storage tank a. Comply with the requirements of subpart WW of this part, except as specified in §63.8010(b); or
    b. Reduce total organic HAP emissions from the storage tank by ≥90 percent by weight by venting emissions through a closed-vent system to any combination of control devices (excluding a flare); or
    c. Reduce total organic HAP emissions from the storage tank by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare.
2. Group 1b storage tank a. Comply with the requirements of subpart WW of this part, except as specified in §63.8010(b); or
    b. Reduce total organic HAP emissions from the storage tank by ≥80 percent by weight by venting emissions through a closed-vent system to any combination of control devices (excluding a flare); or
    c. Reduce total organic HAP emissions from the storage tank by venting emissions from a non-halogenated vent stream through a closed-vent system to a flare.