Open Table
For the air pollutant You must meet this
emission limitation2
Using this averaging time3 And determining compliance using this method3
Cadmium 0.004 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part).
Carbon monoxide 157 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 10, 10A, or 10B, of appendix A of this part).
Dioxins/furans (toxic equivalency basis) 0.41 nanograms per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 23 of appendix A of this part).
Hydrogen chloride 62 parts per million by dry volume 3-run average (For Method 26, collect a minimum volume of 120 liters per run. For Method 26A, collect a minimum volume of 1 dry standard cubic meter per run) Performance test (Method 26 or 26A at 40 CFR part 60, appendix A-8).
Lead 0.04 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 of appendix A of this part).
Mercury 0.47 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 29 or 30B at 40 CFR part 60, appendix A-8) or ASTM D6784-02 (Reapproved 2008).4
Opacity 10 percent Three 1-hour blocks consisting of ten 6-minute average opacity values Performance test (Method 9 at 40 CFR part 60, appendix A-4).
Nitrogen oxides 388 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Methods 7 or 7E at 40 CFR part 60, appendix A-4).
Particulate matter 70 milligrams per dry standard cubic meter 3-run average (1 hour minimum sample time per run) Performance test (Method 5 or 29 of appendix A of this part).
Sulfur dioxide 20 parts per million by dry volume 3-run average (1 hour minimum sample time per run) Performance test (Method 6 or 6c of appendix A of this part).

1Applies only to incinerators subject to the CISWI standards through a state plan or the Federal plan prior to June 4, 2010. The date specified in the state plan can be no later than 3 years after the effective date of approval of a revised state plan or February 7, 2018.

2All emission limitations (except for opacity) are measured at 7 percent oxygen, dry basis at standard conditions.

3In lieu of performance testing, you may use a CEMS or, for mercury, an integrated sorbent trap monitoring system, to demonstrate initial and continuing compliance with an emissions limit, as long as you comply with the CEMS or integrated sorbent trap monitoring system requirements applicable to the specific pollutant in §§60.2710 and 60.2730. As prescribed in §60.2710(u), if you use a CEMS or integrated sorbent trap monitoring system to demonstrate compliance with an emissions limit, your averaging time is a 30-day rolling average of 1-hour arithmetic average emission concentrations.

4Incorporated by reference, see §60.17.