As stated in §§63.6100 and 63.6140, you must comply with the following operating limitations.

Open Table
For .  .  . You must .  .  .
1. each stationary combustion turbine that is required to comply with the emission limitation for formaldehyde and is using an oxidation catalyst maintain the 4-hour rolling average of the catalyst inlet temperature within the range suggested by the catalyst manufacturer. You are not required to use the catalyst inlet temperature data that is recorded during engine startup in the calculations of the 4-hour rolling average catalyst inlet temperature.
2. each stationary combustion turbine that is required to comply with the emission limitation for formaldehyde and is not using an oxidation catalyst maintain any operating limitations approved by the Administrator.

[85 FR 13542, Mar. 9, 2020]