Open Table
If you operate a(n) .  .  . You must .  .  . Or you must .  .  .
(1) Thermal oxidizer Maintain the 3-hour block average firebox temperature above the minimum temperature established during the performance test Maintain the 3-hour block average THC concentrationa in the thermal oxidizer exhaust below the maximum concentration established during the performance test.
(2) Catalytic oxidizer Maintain the 3-hour block average catalytic oxidizer temperature above the minimum temperature established during the performance test; AND check the activity level of a representative sample of the catalyst at least every 12 months Maintain the 3-hour block average THC concentrationa in the catalytic oxidizer exhaust below the maximum concentration established during the performance test.
(3) Biofilter Maintain the 24-hour block biofilter bed temperature within the range established according to §63.2262(m) Maintain the 24-hour block average THC concentrationa in the biofilter exhaust below the maximum concentration established during the performance test.
(4) Control device other than a thermal oxidizer, catalytic oxidizer, or biofilter Petition the EPA Administrator for site-specific operating parameter(s) to be established during the performance test and maintain the average operating parameter(s) within the range(s) established during the performance test Maintain the 3-hour block average THC concentrationa in the control device exhaust below the maximum concentration established during the performance test.
(5) Process unit that meets a compliance option in Table 1A of this subpart, or a process unit that generates debits in an emissions average without the use of a control device Maintain on a daily basis the process unit controlling operating parameter(s) within the ranges established during the performance test according to §63.2262(n) Maintain the 3-hour block average THC concentrationa in the process unit exhaust below the maximum concentration established during the performance test.

aYou may choose to subtract methane from THC measurements.