40 CFR Table 39
Continuous Compliance With Work Practice Standards for HAP Emissions From Bypass Lines
June 9, 2020
As stated in §63.1569(c)(1), you shall meet each requirement in the following table that applies to you.
Open Table
If you elect this standard . . . | You shall demonstrate continuous compliance by . . . |
---|---|
1. Option 1: Flow indicator, level recorder, or electronic valve position monitor. | Monitoring and recording on a continuous basis or at least every hour whether flow is present in the bypass line; visually inspecting the device at least once every hour if the device is not equipped with a recording system that provides a continuous record; and recording whether the device is operating properly and whether flow is present in the bypass line. |
2. Option 2: Car-seal or lock-and-key device | Visually inspecting the seal or closure mechanism at least once every month; and recording whether the bypass line valve is maintained in the closed position and whether flow is present in the line. |
3. Option 3: Solid blind flange | Visually inspecting the blind at least once a month; and recording whether the blind is maintained in the correct position such that the vent stream cannot be diverted through the bypass line. |
4. Option 4: Vent to control device | Monitoring the control device according to appropriate subpart requirements. |
5. Option 1, 2, 3, or 4 | Recording and reporting the time and duration of any bypass. |
[67 FR 17773, Apr. 11, 2002, as amended at 70 FR 6942, 6965, Feb. 9, 2005]