Open Table
Operating
parameters
to be
monitored
Minimum frequency HMIWI
Data measurement Data recording HMIWI with combustion control only HMIWI with dry scrubber followed by FF HMIWI with wet scrubber HMIWI with dry scrubber followed by FF and wet scrubber HMIWI with SNCR system
Maximum operating parameters:
Maximum charge rate Once per charge Once per charge
Maximum FF inlet temperature Continuous Once per minute
Maximum flue gas temperature Continuous Once per minute
Minimum operating parameters:
Minimum secondary chamber temperature Continuous Once per minute
Minimum dioxin/furan sorbent flow rate Hourly Once per hour
Minimum HCl sorbent flow rate Hourly Once per hour
Minimum mercury (Hg) sorbent flow rate Hourly Once per hour
Minimum pressure drop across the wet scrubber or minimum horsepower or amperage to wet scrubber Continuous Once per minute
Minimum scrubber liquor flow rate Continuous Once per minute
Minimum scrubber liquor pH Continuous Once per minute
Minimum reagent flow rate Hourly Once per hour

[78 FR 28076, May 13, 2013]