As required in §63.2470, you must meet each emission limit in the following table that applies to your storage tanks:

Open Table
For each  .  .  . For which  .  .  . Then you must  .  .  .
1. Group 1 storage tank a. The maximum true vapor pressure of total HAP at the storage temperature is ≥76.6 kilopascals i. Reduce total HAP emissions by ≥95 percent by weight or to ≤20 ppmv of TOC or organic HAP and ≤20 ppmv of hydrogen halide and halogen HAP by venting emissions through a closed vent system to any combination of control devices (excluding a flare); or
    ii. Reduce total organic HAP emissions by venting emissions through a closed vent system to a flare; or
    iii. Reduce total HAP emissions by venting emissions to a fuel gas system or process in accordance with §63.982(d) and the requirements referenced therein.
    b. The maximum true vapor pressure of total HAP at the storage temperature is <76.6 kilopascals i. Comply with the requirements of subpart WW of this part, except as specified in §63.2470; or
    ii. Reduce total HAP emissions by ≥95 percent by weight or to ≤20 ppmv of TOC or organic HAP and ≤20 ppmv of hydrogen halide and halogen HAP by venting emissions through a closed vent system to any combination of control devices (excluding a flare); or
    iii. Reduce total organic HAP emissions by venting emissions through a closed vent system to a flare; or
    iv. Reduce total HAP emissions by venting emissions to a fuel gas system or process in accordance with §63.982(d) and the requirements referenced therein.
2. Halogenated vent stream from a Group 1 storage tank You use a combustion control device to control organic HAP emissions Meet one of the emission limit options specified in Item 2.a.i or ii. in Table 1 to this subpart.

[68 FR 63888, Nov. 10, 2003, as amended at 71 FR 40340, July 14, 2006]