As stated in §63.8806, you must comply with the requirements to demonstrate initial compliance with the applicable emission limits in the following table:

Open Table
For .  .  . For the following emission limit .  .  . You have demonstrated initial compliance if .  .  .
1. Each new, reconstructed, or existing loop slitter adhesive use affected source Eliminate use of HAP-based adhesives You do not use HAP-based adhesives.
2. Each new or reconstructed flame lamination affected source using a scrubber Reduce HAP emissions by 90 percent The average HAP emissions, measured over the period of the performance test(s), are reduced by 90 percent.
3. Each new or reconstructed flame lamination affected source using any other control device emissions by Reduce HAP emissions by 90 percent The average HAP emissions, measured over the period of the performance test(s), are reduced by 90 percent.

Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.