As stated in §63.6665, you must comply with the following applicable general provisions.
Open Table
General provisions citation | Subject of citation | Applies to subpart | Explanation |
---|---|---|---|
§63.1 | General applicability of the General Provisions | Yes. | |
§63.2 | Definitions | Yes | Additional terms defined in §63.6675. |
§63.3 | Units and abbreviations | Yes. | |
§63.4 | Prohibited activities and circumvention | Yes. | |
§63.5 | Construction and reconstruction | Yes. | |
§63.6(a) | Applicability | Yes. | |
§63.6(b)(1)-(4) | Compliance dates for new and reconstructed sources | Yes. | |
§63.6(b)(5) | Notification | Yes. | |
§63.6(b)(6) | [Reserved] | ||
§63.6(b)(7) | Compliance dates for new and reconstructed area sources that become major sources | Yes. | |
§63.6(c)(1)-(2) | Compliance dates for existing sources | Yes. | |
§63.6(c)(3)-(4) | [Reserved] | ||
§63.6(c)(5) | Compliance dates for existing area sources that become major sources | Yes. | |
§63.6(d) | [Reserved] | ||
§63.6(e) | Operation and maintenance | No. | |
§63.6(f)(1) | Applicability of standards | No. | |
§63.6(f)(2) | Methods for determining compliance | Yes. | |
§63.6(f)(3) | Finding of compliance | Yes. | |
§63.6(g)(1)-(3) | Use of alternate standard | Yes. | |
§63.6(h) | Opacity and visible emission standards | No | Subpart ZZZZ does not contain opacity or visible emission standards. |
§63.6(i) | Compliance extension procedures and criteria | Yes. | |
§63.6(j) | Presidential compliance exemption | Yes. | |
§63.7(a)(1)-(2) | Performance test dates | Yes | Subpart ZZZZ contains performance test dates at §§63.6610, 63.6611, and 63.6612. |
§63.7(a)(3) | CAA section 114 authority | Yes. | |
§63.7(b)(1) | Notification of performance test | Yes | Except that §63.7(b)(1) only applies as specified in §63.6645. |
§63.7(b)(2) | Notification of rescheduling | Yes | Except that §63.7(b)(2) only applies as specified in §63.6645. |
§63.7(c) | Quality assurance/test plan | Yes | Except that §63.7(c) only applies as specified in §63.6645. |
§63.7(d) | Testing facilities | Yes. | |
§63.7(e)(1) | Conditions for conducting performance tests | No. | Subpart ZZZZ specifies conditions for conducting performance tests at §63.6620. |
§63.7(e)(2) | Conduct of performance tests and reduction of data | Yes | Subpart ZZZZ specifies test methods at §63.6620. |
§63.7(e)(3) | Test run duration | Yes. | |
§63.7(e)(4) | Administrator may require other testing under section 114 of the CAA | Yes. | |
§63.7(f) | Alternative test method provisions | Yes. | |
§63.7(g) | Performance test data analysis, recordkeeping, and reporting | Yes. | |
§63.7(h) | Waiver of tests | Yes. | |
§63.8(a)(1) | Applicability of monitoring requirements | Yes | Subpart ZZZZ contains specific requirements for monitoring at §63.6625. |
§63.8(a)(2) | Performance specifications | Yes. | |
§63.8(a)(3) | [Reserved] | ||
§63.8(a)(4) | Monitoring for control devices | No. | |
§63.8(b)(1) | Monitoring | Yes. | |
§63.8(b)(2)-(3) | Multiple effluents and multiple monitoring systems | Yes. | |
§63.8(c)(1) | Monitoring system operation and maintenance | Yes. | |
§63.8(c)(1)(i) | Routine and predictable SSM | No | |
§63.8(c)(1)(ii) | SSM not in Startup Shutdown Malfunction Plan | Yes. | |
§63.8(c)(1)(iii) | Compliance with operation and maintenance requirements | No | |
§63.8(c)(2)-(3) | Monitoring system installation | Yes. | |
§63.8(c)(4) | Continuous monitoring system (CMS) requirements | Yes | Except that subpart ZZZZ does not require Continuous Opacity Monitoring System (COMS). |
§63.8(c)(5) | COMS minimum procedures | No | Subpart ZZZZ does not require COMS. |
§63.8(c)(6)-(8) | CMS requirements | Yes | Except that subpart ZZZZ does not require COMS. |
§63.8(d) | CMS quality control | Yes. | |
§63.8(e) | CMS performance evaluation | Yes | Except for §63.8(e)(5)(ii), which applies to COMS. |
Except that §63.8(e) only applies as specified in §63.6645. | |||
§63.8(f)(1)-(5) | Alternative monitoring method | Yes | Except that §63.8(f)(4) only applies as specified in §63.6645. |
§63.8(f)(6) | Alternative to relative accuracy test | Yes | Except that §63.8(f)(6) only applies as specified in §63.6645. |
§63.8(g) | Data reduction | Yes | Except that provisions for COMS are not applicable. Averaging periods for demonstrating compliance are specified at §§63.6635 and 63.6640. |
§63.9(a) | Applicability and State delegation of notification requirements | Yes. | |
§63.9(b)(1)-(5) | Initial notifications | Yes | Except that §63.9(b)(3) is reserved. |
Except that §63.9(b) only applies as specified in §63.6645. | |||
§63.9(c) | Request for compliance extension | Yes | Except that §63.9(c) only applies as specified in §63.6645. |
§63.9(d) | Notification of special compliance requirements for new sources | Yes | Except that §63.9(d) only applies as specified in §63.6645. |
§63.9(e) | Notification of performance test | Yes | Except that §63.9(e) only applies as specified in §63.6645. |
§63.9(f) | Notification of visible emission (VE)/opacity test | No | Subpart ZZZZ does not contain opacity or VE standards. |
§63.9(g)(1) | Notification of performance evaluation | Yes | Except that §63.9(g) only applies as specified in §63.6645. |
§63.9(g)(2) | Notification of use of COMS data | No | Subpart ZZZZ does not contain opacity or VE standards. |
§63.9(g)(3) | Notification that criterion for alternative to RATA is exceeded | Yes | If alternative is in use. |
Except that §63.9(g) only applies as specified in §63.6645. | |||
§63.9(h)(1)-(6) | Notification of compliance status | Yes | Except that notifications for sources using a CEMS are due 30 days after completion of performance evaluations. §63.9(h)(4) is reserved. |
Except that §63.9(h) only applies as specified in §63.6645. | |||
§63.9(i) | Adjustment of submittal deadlines | Yes. | |
§63.9(j) | Change in previous information | Yes. | |
§63.10(a) | Administrative provisions for recordkeeping/reporting | Yes. | |
§63.10(b)(1) | Record retention | Yes | Except that the most recent 2 years of data do not have to be retained on site. |
§63.10(b)(2)(i)-(v) | Records related to SSM | No. | |
§63.10(b)(2)(vi)-(xi) | Records | Yes. | |
§63.10(b)(2)(xii) | Record when under waiver | Yes. | |
§63.10(b)(2)(xiii) | Records when using alternative to RATA | Yes | For CO standard if using RATA alternative. |
§63.10(b)(2)(xiv) | Records of supporting documentation | Yes. | |
§63.10(b)(3) | Records of applicability determination | Yes. | |
§63.10(c) | Additional records for sources using CEMS | Yes | Except that §63.10(c)(2)-(4) and (9) are reserved. |
§63.10(d)(1) | General reporting requirements | Yes. | |
§63.10(d)(2) | Report of performance test results | Yes. | |
§63.10(d)(3) | Reporting opacity or VE observations | No | Subpart ZZZZ does not contain opacity or VE standards. |
§63.10(d)(4) | Progress reports | Yes. | |
§63.10(d)(5) | Startup, shutdown, and malfunction reports | No. | |
§63.10(e)(1) and (2)(i) | Additional CMS Reports | Yes. | |
§63.10(e)(2)(ii) | COMS-related report | No | Subpart ZZZZ does not require COMS. |
§63.10(e)(3) | Excess emission and parameter exceedances reports | Yes. | Except that §63.10(e)(3)(i) (C) is reserved. |
§63.10(e)(4) | Reporting COMS data | No | Subpart ZZZZ does not require COMS. |
§63.10(f) | Waiver for recordkeeping/reporting | Yes. | |
§63.11 | Flares | No. | |
§63.12 | State authority and delegations | Yes. | |
§63.13 | Addresses | Yes. | |
§63.14 | Incorporation by reference | Yes. | |
§63.15 | Availability of information | Yes. |