40 CFR Table C-3 to Subpart C of Part 53
Test Specifications for Pb in TSP and Pb in PM10 Methods
June 9, 2020
Open Table
Concentration range equivalent to percentage of NAAQS in µg/m3 | 30% to 250% |
Minimum number of 24-hr measurements | 5 |
Maximum reference method analytical bias, Dq | ±5% |
Maximum precision, PR or PC | ≤15% |
Maximum difference (D) | ±20% |
Estimated Method Detection Limit (MDL), µg/m3 | 5% of NAAQS level. |
[73 FR 67059, Nov. 12, 2008]