40 CFR Table W-6A to Subpart W of Part 98
Default Methane Leaker Emission Factors for LNG Import and Export Equipment
June 9, 2020
CFR
Open Table
LNG import and export equipment Emission factor
(scf/hour/component)
If you survey using any of the methods in §98.234(a)(1)
through (6)
If you survey using Method 21 as
specified in
§98.234(a)(7)
Leaker Emission Factors—LNG Terminals Components, LNG Service
Valve 1.19 0.23
Pump Seal 4.00 0.73
Connector 0.34 0.11
Other1 1.77 0.99
Leaker Emission Factors—LNG Terminals Components, Gas Service
Valve2 14.84 9.51
Connector 5.59 3.58
Open-Ended Line 17.27 11.07
Pressure Relief Valve 39.66 25.42
Meter and Instrument 19.33 12.39
Other3 4.1 2.63

1“Other” equipment type for components in LNG service should be applied for any equipment type other than connectors, pumps, or valves.

2Valves include control valves, block valves and regulator valves.

3“Other” equipment type for components in gas service should be applied for any equipment type other than valves, connectors, flanges, open-ended lines, pressure relief valves, and meters and instruments, as specified in §98.232(h)(7) and (8).

[81 FR 86518, Nov. 30, 2016]


Tried the LawStack mobile app?

Join thousands and try LawStack mobile for FREE today.

  • Carry the law offline, wherever you go.
  • Download CFR, USC, rules, and state law to your mobile device.