46 CFR § 153.285
Valving for cargo pump manifolds
April 15, 2021
(a) When cargo lines serving different tanks enter a pumproom and connect to the same pump:
(1) Each cargo line must have a stop valve within the line;
(2) The valve must be before the cargo line joins the other lines or pump; and
(3) The valve must be within the pumproom.
(b) The valve in paragraph (a) of this section is required in addition to any valve required under §153.283(b).