(a) Unless a higher limit is specified on the certificate the master shall ensure that a cargo tank is not loaded:

(1) More than 98 percent liquid full; or

(2) In excess of the volume determined under the following formula:

eCFR graphic ec02fe91.089.gif

where:

VL = maximum volume to which the tank may be loaded;

V = volume of the tank;

dr = density at the reference temperature specified in paragraph (b) of this section; and

dL = density of the cargo at the loading temperature and pressure.

(b) The reference temperature to be used in paragraph (a)(2) of this section is the temperature corresponding to the vapor pressure of the cargo at the set pressure of the pressure relief valves.