46 CFR § 154.520
Piping calculations
April 15, 2021
A piping system must be designed to meet the allowable stress values under §56.07-10 of this chapter and, if the design temperature is −110 °C (−166 °F) or lower, the stress analysis must be specially approved by the Commandant (CG-ENG) and must include:
(a) Pipe weight loads;
(b) Acceleration loads;
(c) Internal pressure loads;
(d) Thermal loads; and
(e) Loads from the hull.
[CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]