Each servicing facility approved by the Coast Guard must maintain equipment to carry out the operations described in the manufacturer's servicing manual approved in accordance with §160.151-35(b)(1), including—
(a) A set of plans, as specified in §160.151-35(b)(3), for each inflatable liferaft to be serviced;
(b) A current copy of this subpart;
(c) A current copy of the manual approved in accordance with §160.151-35(b)(1), including all revisions and bulletins in effect as indicated on the annual list issued in accordance with §160.151-35(b)(2);
(d) Hot presses (if applicable);
(e) Safety-type glue pots or equivalents;
(f) Abrasive devices;
(g) A source of clean, dry, pressurized air; hoses; and attachments for inflating liferafts;
(h) A source of vacuum; hoses; and attachments for deflating liferafts;
(i) Mercury manometer, water manometer, or other pressure-measurement device or pressure gauge of equivalent accuracy and sensitivity;
(j) Thermometer;
(k) Barometer, aneroid or mercury;
(l) Calibrated torque-wrench for assembling the inflation system;
(m) Accurate weighing scale;
(n) Repair materials and equipment, and spare parts as specified in the applicable manual, except that items of limited “shelf life” need not be stocked if they are readily available;
(o) A complete stock of the survival equipment required to be stowed in the liferafts, except for items of equipment that are readily available;
(p) A means for load-testing davit-launched liferafts, unless the facility services only non-davit-launched liferafts;
(q) A supply of parts for all inflation components and valves specified in the applicable manual; and
(r) A tool board that clearly indicates where each small tool is stored, or has an equivalent means to make sure that no tools are left in the liferaft when repacked.