Except as provided in §238.441 of this chapter—
(a) Number and dimensions. Each passenger car ordered on or after April 1, 2009, or placed in service for the first time on or after April 1, 2011, shall have a minimum of two emergency roof access locations, each with a minimum opening of 26 inches longitudinally (i.e., parallel to the longitudinal axis of the car) by 24 inches laterally.
(b) Means of access. Emergency roof access shall be provided by means of a hatch, or a conspicuously marked structural weak point in the roof for access by properly equipped emergency response personnel.
(c) Location. Emergency roof access locations shall be situated as practical so that when a car is on its side—
(1) One emergency access location is wholly within each half of the roof as divided top from bottom; and
(2) One emergency access location is wholly within each half of the roof as divided left from right. (See Figure 3 to this subpart.)
(d) Obstructions. The ceiling space below each emergency roof access location shall be free from wire, cabling, conduit, and piping. This space shall also be free of any rigid secondary structure (e.g., a diffuser or diffuser support, lighting back fixture, mounted PA equipment, or luggage rack) where practicable. If emergency roof access is provided by means of a hatch, it shall be possible to push interior panels or liners out of their retention devices and into the interior of the vehicle after removing the hatch. If emergency roof access is provided by means of a structural weak point, it shall be permissible to cut through interior panels, liners, or other non-rigid secondary structures after making the cutout hole in the roof, provided any such additional cutting necessary to access the interior of the vehicle permits a minimum opening of the dimensions specified in paragraph (a) to be maintained.
(e) Marking and instructions.
(1) Prior to January 28, 2015, each emergency roof access location shall be conspicuously marked with retroreflective material of contrasting color. As further specified, legible and understandable instructions shall be posted at or near each such location. If emergency roof access is provided by means of a structural weak point—
(i) The retroreflective material shall conspicuously mark the line along which the roof skin shall be cut; and
(ii) A sign plate with a retroreflective border shall also state as follows:
CAUTION—DO NOT USE FLAME CUTTING DEVICES
CAUTION—WARN PASSENGERS BEFORE CUTTING
CUT ALONG DASHED LINE TO GAIN ACCESS
ROOF CONSTRUCTION—[STATE RELEVANT DETAILS]
(2) On or after January 28, 2015, each emergency roof access location shall be marked, and instructions provided for its use, as specified in §238.125.
[73 FR 6403, Feb. 1, 2008, as amended at 78 FR 71814, Nov. 29, 2013]