(a) You must meet each emission limit in Table 1 to this subpart that applies to you.
(b) You must meet each operating limit for control devices in paragraphs (b)(1) through (5) of this section that applies to you.
(1) Except as provided in paragraph (b)(2) of this section, for each wet scrubber applied to meet any particulate matter emission limit in Table 1 to this subpart, you must maintain the daily average pressure drop and daily average scrubber water flow rate at or above the minimum levels established during the initial performance test.
(2) For each dynamic wet scrubber applied to meet any particulate matter emission limit in Table 1 to this subpart, you must maintain the daily average scrubber water flow rate and either the daily average fan amperage (a surrogate for fan speed as revolutions per minute) or the daily average pressure drop at or above the minimum levels established during the initial performance test.
(3) For each dry electrostatic precipitator applied to meet any particulate matter emission limit in Table 1 to this subpart, you must meet the operating limits in paragraph (b)(3)(i) or (ii) of this section.
(i) Maintain the 6-minute average opacity of emissions exiting the control device stack at or below the level established during the initial performance test.
(ii) Maintain the daily average secondary voltage and daily average secondary current for each field at or above the minimum levels established during the initial performance test.
(4) For each wet electrostatic precipitator applied to meet any particulate matter emission limit in Table 1 to this subpart, you must meet the operating limits in paragraphs (b)(4)(i) through (iii) of this section.
(i) Maintain the daily average secondary voltage for each field at or above the minimum levels established during the initial performance test.
(ii) Maintain the daily average stack outlet temperature at or below the maximum levels established during the initial performance test.
(iii) Maintain the daily average water flow rate at or above the minimum levels established during the initial performance test.
(5) If you use any air pollution control device other than a baghouse, wet scrubber, dynamic scrubber, dry electrostatic precipitator, or wet electrostatic precipitator, you must submit a site-specific monitoring plan in accordance with §63.9631(f).
(c) You may petition the Administrator for approval of alternatives to the monitoring requirements in paragraphs (b)(1) through (4) of this section as allowed under §63.8(f) and as defined in §63.90.