Search returned 328145 results for "free fc coins xbox one Visit Buyfc26coins.com for latest FC 26 coins news..yEY9"
This account must include the cost of land and land rights used for service company purposes, the cost of which is not properly includible in other land and land rights accounts (See Service Company Property Instructions in §367.55).
The said area or areas shall be permanently reserved as a wilderness, and no development of the project or plan for the entertainment of visitors shall be undertaken which will interfere with the preservation intact of the unique flora and fauna and the essential primitive natural conditions now prevailing in this area.
The requirements for generators contained in §111.12-5 apply to motors. [CGD 74-125A, 47 FR 15236, Apr. 8, 1982, as amended by CGD 94-108, 62 FR 23908, May 1, 1997]
Spare parts and repair equipment must be provided for each lifesaving appliance and component that either is subject to excessive wear or consumption or needs to be replaced regularly. These parts and equipment must be kept aboard the OSV, except that, if the vessel operates daily out of the same shore base, they may be kept at that base.
Each control cabinet or space containing a valve or manifold for a fire extinguishing system must be distinctly marked in conspicuous red letters at least 2 inches high: “[CARBON DIOXIDE/HALON/CLEAN AGENT] FIRE APPARATUS”, as appropriate. [USCG-2006-24797, 77 FR 33884, June 7, 2012]
Each watertight door in a bulkhead that must be watertight in compliance with the requirements in part 174 of this chapter, and each watertight hatch, must be marked on both sides in letters at least 50 millimeters (2 inches) high that state the following: “WATERTIGHT DOOR—KEEP CLOSED EXCEPT FOR PASSAGE” or “WATERTIGHT HATCH—KEEP CLOSED WHEN NOT IN USE”.
On the date the Secretary approves the program under section 3333 of this title, the State shall be treated as having expended such portion of $32,000,000 as the State deems appropriate for purposes of implementing the program.
A refrigeration system for butadiene or vinyl chloride must not use vapor compression unless it: (a) Avoids any stagnation points where uninhibited liquid can accumulate; or (b) Has inhibited liquid from the cargo tank added to the vapor upstream of the condenser.
Except for deck tanks and their piping systems, cargo containment systems and piping systems carrying nitrogen must be specially approved by the Commandant (CG-OES). [CGD 74-289, 44 FR 26009, May 3, 1979, as amended by CGD 82-063b, 48 FR 4782, Feb. 3, 1983]
All materials used in nonstandard life preservers must be equivalent to those specified in §160.055-3 for standard life preservers. [CGD 72-163R, 38 FR 8121, Mar. 28, 1973]