Each powerplant control must be located, arranged, and designed under §§ 25.777 through 25.781 and marked under § 25.1555. In addition, it must meet the following requirements:
- (a)Each control must be located so that it cannot be inadvertently operated by persons entering, leaving, or moving normally in, the cockpit.
- (b)Each flexible control must be approved or must be shown to be suitable for the particular application.
- (c)Each control must have sufficient strength and rigidity to withstand operating loads without failure and without excessive deflection.
- (d)Each control must be able to maintain any set position without constant attention by flight crewmembers and without creep due to control loads or vibration.
- (e)The portion of each powerplant control located in a designated fire zone that is required to be operated in the event of fire must be at least fire resistant.
- (f)For powerplant valve controls located in the flight deck there must be a means: