14 CFR §25.1411
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Accessibility. Required safety equipment to be used by the crew in an emergency must be readily accessible.
- (b)Stowage provisions. Stowage provisions for required emergency equipment must be furnished and must—
- (c)Emergency exit descent device. The stowage provisions for the emergency exit descent devices required by § 25.810(a) must be at each exit for which they are intended.
- (d)Liferafts.
- (1)The stowage provisions for the liferafts described in § 25.1415 must accommodate enough rafts for the maximum number of occupants for which certification for ditching is requested.
- (2)Liferafts must be stowed near exits through which the rafts can be launched during an unplanned ditching.
- (3)Rafts automatically or remotely released outside the airplane must be attached to the airplane by means of the static line prescribed in § 25.1415.
- (4)The stowage provisions for each portable liferaft must allow rapid detachment and removal of the raft for use at other than the intended exits.
- (e)Long-range signaling device. The stowage provisions for the long-range signaling device required by § 25.1415 must be near an exit available during an unplanned ditching.
- (f)Life preserver stowage provisions. The stowage provisions for life preservers described in § 25.1415 must accommodate one life preserver for each occupant for which certification for ditching is requested. Each life preserver must be within easy reach of each seated occupant.
- (g)Life line stowage provisions. If certification for ditching under § 25.801 is requested, there must be provisions to store life lines. These provisions must—