14 CFR §25.625
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
For each fitting (a part or terminal used to join one structural member to another), the following apply:
- (a)For each fitting whose strength is not proven by limit and ultimate load tests in which actual stress conditions are simulated in the fitting and surrounding structures, a fitting factor of at least 1.15 must be applied to each part of—
- (b)No fitting factor need be used—
- (c)For each integral fitting, the part must be treated as a fitting up to the point at which the section properties become typical of the member.
- (d)For each seat, berth, safety belt, and harness, the fitting factor specified in § 25.785(f)(3) applies.