14 CFR §25.869
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Electrical system components:
- (1)Components of the electrical system must meet the applicable fire and smoke protection requirements of §§ 25.831(c) and 25.863.
- (2)Equipment that is located in designated fire zones and is used during emergency procedures must be at least fire resistant.
- (3)EWIS components must meet the requirements of § 25.1713.
- (b)Each vacuum air system line and fitting on the discharge side of the pump that might contain flammable vapors or fluids must meet the requirements of § 25.1183 if the line or fitting is in a designated fire zone. Other vacuum air systems components in designated fire zones must be at least fire resistant.
- (c)Oxygen equipment and lines must—
- (1)Not be located in any designated fire zone,
- (2)Be protected from heat that may be generated in, or escape from, any designated fire zone, and
- (3)Be installed so that escaping oxygen cannot cause ignition of grease, fluid, or vapor accumulations that are present in normal operation or as a result of failure or malfunction of any system.