16 CFR §1211.6
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)A residential garage door operator system shall be provided with inherent primary entrapment protection that complies with the requirements as specified in § 1211.7.
- (b)In addition to the inherent primary entrapment protection as required by paragraph (a) of this section, a vertically moving residential garage door operator shall comply with one of the following:
- (1)Shall be constructed to:
- (i)Require constant pressure on a control intended to be installed and activated within line of sight of the door to lower the door;
- (ii)Reverse direction and open the door to the upmost position when constant pressure on a control is removed prior to operator reaching its lower limit, and
- (iii)Limit a portable transmitter, when supplied, to function only to cause the operator to open the door;
- (2)Shall be provided with a means for connection of an external secondary entrapment protection device as described in § 1211.8 (a) and (c) through (e), as applicable to vertically moving doors; or
- (3)
- (i)Shall be provided with an inherent secondary entrapment protection device as described in §§ 1211.8(a) and (f), 1211.10, and 1211.12 and is:
- (ii)With respect to § 1211.6(b)(3)(i)(A), trolley-driven operators do not meet the definition of a combination sectional overhead garage door operator system.
- (1)Shall be constructed to:
- (c)In the case of a vertically moving combination sectional overhead garage door operator system, the door shall comply with the requirements in ANSI/DASMA 102 (incorporated by reference, see § 1211.40).
- (d)In addition to the inherent primary entrapment protection as required by § 1211.6(a), a horizontally sliding residential garage door operator shall comply with one of the following:
- (1)Shall be constructed to:
- (i)Require constant pressure on a control to close the door;
- (ii)Reverse direction and open the door a minimum of 2 in (50.8 mm) when constant pressure on a control is removed prior to operator reaching its position limit; and
- (iii)Stop the door if a second obstruction is detected in the reverse direction.
- (2)Shall be provided with a means for connection of an external secondary entrapment protection device for each leading edge as described in § 1211.8(c) through (e), as applicable to horizontally moving doors.
- (1)Shall be constructed to:
- (e)A mechanical switch or a relay used in an entrapment protection circuit of an operator shall withstand 100,000 cycles of operation controlling a load no less severe (voltage, current, power factor, inrush and similar ratings) than it controls in the operator, and shall function normally upon completion of the test.
- (f)In addition to complying with paragraph (e) of this section, in the event of a malfunction of a switch or relay (open or short) described in paragraph (c) of this section results in loss of any entrapment protection required by § 1211.7(a), § 1211.7(b)(7), § 1211.7(c)(7), § 1211.8(a), or § 1211.8(b), the door operator shall become inoperative at the end of the opening or closing operation, the door operator shall move the door to, and stay within, 1 foot (305 mm) of the uppermost position.