29 CFR §1910.244 — Other portable tools and equipment.
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Jacks
- (1)Loading and marking.
- (2)Operation and maintenance.
- (i)In the absence of a firm foundation, the base of the jack shall be blocked. If there is a possibility of slippage of the cap, a block shall be placed in between the cap and the load.
- (ii)The operator shall watch the stop indicator, which shall be kept clean, in order to determine the limit of travel. The indicated limit shall not be overrun.
- (iii)After the load has been raised, it shall be cribbed, blocked, or otherwise secured at once.
- (iv)Hydraulic jacks exposed to freezing temperatures shall be supplied with an adequate antifreeze liquid.
- (v)All jacks shall be properly lubricated at regular intervals.
- (vi)Each jack shall be thoroughly inspected at times which depend upon the service conditions. Inspections shall be not less frequent than the following:
- (vii)Repair or replacement parts shall be examined for possible defects.
- (viii)Jacks which are out of order shall be tagged accordingly, and shall not be used until repairs are made.
- (b)Abrasive blast cleaning nozzles. The blast cleaning nozzles shall be equipped with an operating valve which must be held open manually. A support shall be provided on which the nozzle may be mounted when it is not in use.