StacksVerified U.S. regulatory reference

40 CFR §1066.820

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
  1. (a)Determine the mass of exhaust emissions of each pollutant for each FTP test interval as described in § 1066.605.
  2. (b)Calculate the final composite gaseous test results as a mass-weighted value, e[emission]-FTPcomp, in grams per mile using the following equation:
  3. (c)Calculate the final composite PM test results as a mass-weighted value, ePM-FTPcomp, in grams per mile as follows:
    1. (1)Use the following equation for PM measured as described in § 1066.815(b)(1), (2), or (3):
    2. (2)Use the following equation for PM measured as described in § 1066.815(b)(4):
    3. (3)Use the following equation for PM measured as described in § 1066.815(b)(5):