40 CFR §147.305
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)The owner or operator converting an existing well to an injection well shall check the condition of the casing with one of the following logging tools:
- (b)The owner or operator of a new injection well cased with plastic (PVC, ABS, and others) casings shall:
- (c)The owner or operator of a newly drilled well shall install centralizers as directed by the Regional Administrator.
- (d)The owner or operator shall as required by the Regional Administrator:
- (1)Protect USDWs by:
- (2)Isolate any injection zones by placing sufficient cement to fill the calculated space between the casing and the well bore to a point 250 feet above the injection zone; and
- (3)Use cement:
- (4)The Regional Administrator may approve alternate casing and cementing practices provided that the owner or operator demonstrates that such practices will adequately protect USDWs.
- (e)Area of review. Notwithstanding the alternatives presented in § 146.6 of this chapter, the area of review shall be a fixed radius as described in § 146.6(b) of this chapter.
- (f)The applicant must give separate notice of intent to apply for a permit to each owner or tenant of the land within one-quarter mile of the site. The addresses of those to whom notice is given, and a description of how notice is given, shall be submitted with the permit application. The notice shall include:
- (1)Name and address of applicant;
- (2)A brief description of the planned injection activities, including well location, name and depth of the injection zone, maximum injection pressure and volume, and fluid to be injected;
- (3)EPA contact person; and
- (4)A statement that opportunity to comment will be announced after EPA prepares a draft permit. This requirement may be waived by the Regional Administrator when he determines that individual notice to all land owners and tenants would be impractical.