40 CFR §60.186
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)In conducting the performance tests required in § 60.8, the owner or operator shall use as reference methods and procedures the test methods in appendix A of this part or other methods and procedures as specified in this section, except as provided in § 60.8(b).
- (b)The owner or operator shall determine compliance with the particulate matter, sulfur dioxide (SO2), and visible emission standards in §§ 60.182, 60.183, and 60.184 as follows:
- (1)Method 5 shall be used to determine the particulate matter concentration. The sampling time and sample volume for each run shall be at least 60 minutes and 0.85 dscm (30 dscf).
- (2)The continuous monitoring system of § 60.185(a)(2) shall be used to determine the SO2 concentrations on a dry basis. The sampling time for each run shall be 2 hours, and the average SO2 concentration for the 2-hour period shall be computed as in § 60.185(b). The monitoring system drift during the run may not exceed 2 percent of the span value.
- (3)Method 9 and the procedures in § 60.11 shall be used to determine opacity.