(1)An owner or operator shall comply initially with the requirements for valves in gas/vapor service and valves in light liquid service, as described in § 60.482-7b.
(2)After 2 consecutive quarterly leak detection periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 1 of the quarterly leak detection periods for the valves in gas/vapor and light liquid service.
(3)After 5 consecutive quarterly leak detection periods with the percent of valves leaking equal to or less than 2.0, an owner or operator may begin to skip 3 of the quarterly leak detection periods for the valves in gas/vapor and light liquid service.
(4)If the percent of valves leaking is greater than 2.0, the owner or operator shall comply with the requirements as described in § 60.482-7b but can again elect to use this section.
(5)The percent of valves leaking shall be determined as described in § 60.485b(h).
(6)An owner or operator must keep a record of the percent of valves found leaking during each leak detection period.
(7)A valve that begins operation in gas/vapor service or light liquid service after the initial startup date for a process unit following one of the alternative standards in this section must be monitored in accordance with § 60.482-7b(a)(2)(i) or (ii) before the provisions of this section can be applied to that valve.