StacksVerified U.S. regulatory reference

40 CFR §61.242-7

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
  1. (a)Each valve shall be monitored monthly to detect leaks by the method specified in § 61.245(b) and shall comply with paragraphs (b)-(e), except as provided in paragraphs (f), (g), and (h) of this section, § 61.243-1 or § 61.243-2, and § 61.242-1(c).
  2. (b)If an instrument reading of 10,000 ppm or greater is measured, a leak is detected.
  3. (c)
    1. (1)Any valve for which a leak is not detected for 2 successive months may be monitored the first month of every quarter, beginning with the next quarter, until a leak is detected.
    2. (2)If a leak is detected, the valve shall be monitored monthly until a leak is not detected for 2 successive months.
  4. (d)
    1. (1)When a leak is detected, it shall be repaired as soon as practicable, but no later than 15 calendar days after the leak is detected, except as provided in § 61.242-10.
    2. (2)A first attempt at repair shall be made no later than 5 calendar days after each leak is detected.
  5. (e)First attempts at repair include, but are not limited to, the following best practices where practicable:
    1. (1)Tightening of bonnet bolts;
    2. (2)Replacement of bonnet bolts;
    3. (3)Tightening of packing gland nuts; and
    4. (4)Injection of lubricant into lubricated packing.
  6. (f)Any valve that is designated, as described in § 61.246(e)(2), for no detectable emissions, as indicated by an instrument reading of less than 500 ppm above background, is exempt from the requirements of paragraph (a) if the valve:
    1. (1)Has no external actuating mechanism in contact with the process fluid;
    2. (2)Is operated with emissions less than 500 ppm above background, as measured by the method specified in § 61.245(c); and
    3. (3)Is tested for compliance with paragraph (f)(2) initially upon designation, annually, and at other times requested by the Administrator.
  7. (g)Any valve that is designated, as described in § 61.246(f)(1), as an unsafe-to-monitor valve is exempt from the requirements of paragraph (a) if:
    1. (1)The owner or operator of the valve demonstrates that the valve is unsafe to monitor because monitoring personnel would be exposed to an immediate danger as a consequence of complying with paragraph (a); and
    2. (2)The owner or operator of the valve has a written plan that requires monitoring of the valve as frequent as practicable during safe-to-monitor times.
  8. (h)Any valve that is designated, as described in § 61.246(f)(2), as a difficult-to-monitor valve is exempt from the requirements of paragraph (a) if:
    1. (1)The owner or operator of the valve demonstrates that the valve cannot be monitored without elevating the monitoring personnel more than 2 meters above a support surface;
    2. (2)The process unit within which the valve is located is an existing process unit; and
    3. (3)The owner or operator of the valve follows a written plan that requires monitoring of the valve at least once per calendar year.