40 CFR §62.14650
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)All performance tests must consist of a minimum of three test runs conducted under conditions representative of normal operations.
- (b)You must document that the waste burned during the performance test is representative of the waste burned under normal operating conditions by maintaining a log of the quantity of waste burned (as required in § 62.14700(b)(1)) and the types of waste burned during the performance test.
- (c)All performance tests must be conducted using the minimum run duration specified in Table 1 of this subpart.
- (d)Method 1 of 40 CFR part 60, appendix A must be used to select the sampling location and number of traverse points.
- (e)Method 3A or 3B of 40 CFR part 60, appendix A must be used for gas composition analysis, including measurement of oxygen concentration. Method 3A or 3B of 40 CFR part 60, appendix A must be used simultaneously with each method.
- (f)All pollutant concentrations, except for opacity, must be adjusted to 7 percent oxygen using Equation 1 of this section:
- (g)You must determine dioxins/furans toxic equivalency by following the procedures in paragraphs (g)(1) through (3) of this section.
- (1)Measure the concentration of each dioxin/furan tetra- through octa-congener emitted using EPA Method 23.
- (2)For each dioxin/furan congener measured in accordance with paragraph (g)(1) of this section, multiply the congener concentration by its corresponding toxic equivalency factor specified in Table 3 of this subpart.
- (3)Sum the products calculated in accordance with paragraph (g)(2) of this section to obtain the total concentration of dioxins/furans emitted in terms of toxic equivalency.