40 CFR §63.1085
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Unless you meet one of the requirements for exemptions in § 63.1084, you must meet the requirements in paragraphs (a) through (f) of this section.
- (a)Except as specified in paragraph (e) of this section, you must monitor the cooling water for the presence of substances that indicate a leak according to § 63.1086(a) through (d).
- (b)Except as specified in paragraph (f) of this section, if you detect a leak, then you must repair it according to § 63.1087(a) and (b) unless repair is delayed according to § 63.1088(a) through (c).
- (c)Keep the records specified in § 63.1089.
- (d)Submit the reports specified in § 63.1090.
- (e)Beginning no later than the compliance dates specified in § 63.1081(a), the requirements specified in § 63.1086(a) through (d) no longer apply; instead, you must monitor the cooling water for the presence of total strippable hydrocarbons that indicate a leak according to § 63.1086(e). At any time before the compliance dates specified in § 63.1081(a), you may choose to comply with the requirements in this paragraph in lieu of the requirements in paragraph (a) of this section.
- (f)Beginning no later than the compliance dates specified in § 63.1081(a), the requirements specified in §§ 63.1087(a) and (b) and 63.1088(a) through (c), no longer apply; instead, if you detect a leak, then you must repair it according to § 63.1087(c) and (d), unless repair is delayed according to § 63.1088(d). At any time before the compliance dates specified in § 63.1081(a), you may choose to comply with the requirements in this paragraph in lieu of the requirements in paragraph (b) of this section.