40 CFR §63.1181
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
To comply with the PM standards, you must meet all of the following:
- (a)Install, adjust, maintain, and continuously operate a bag leak detection system for each fabric filter.
- (b)Do a performance test as specified in § 63.1188 of this subpart and show compliance with the PM emission limits while the bag leak detection system is installed, operational, and properly adjusted.
- (c)Begin corrective actions specified in your operations, maintenance, and monitoring plan required by § 63.1187 of this subpart within one hour after the alarm on a bag leak detection system sounds. Complete the corrective actions in a timely manner.
- (d)Develop and implement a written QIP consistent with compliance assurance monitoring requirements of 40 CFR 64.8(b) through (d) when the alarm on a bag leak detection system sounds for more than five percent of the total operating time in a six-month reporting period.