You must use the following test methods to determine compliance with the applicable emission limits:
  1. (a)Method 1 in appendix A to part 60 of this chapter for the selection of the sampling port locations and number of sampling ports.
  2. (b)Method 2 in appendix A to part 60 of this chapter for stack gas velocity and volumetric flow rate.
  3. (c)Method 3 or 3A in appendix A to part 60 of this chapter for oxygen and carbon dioxide for diluent measurements needed to correct the concentration measurements to a standard basis.
  4. (d)Method 4 in appendix A to part 60 of this chapter for moisture content of the stack gas.
  5. (e)Method 5 in appendix A to part 60 of this chapter for the concentration of PM. Each PM test run must consist of a minimum run time of three hours and a minimum sample volume of 3.75 dscm (135 dscf).
  6. (f)Method 10 in appendix A to part 60 of this chapter for the concentration of CO, using the continuous sampling option described in section 7.1.1 of the method. Each CO test run must consist of a minimum run time of one hour.
  7. (g)Method 318 at 40 CFR part 60, appendix A to this part for the concentration of formaldehyde, phenol, methanol, and carbonyl sulfide.
  8. (h)Method to determine the free-formaldehyde content of each resin lot in appendix A of this subpart.
  9. (i)Method 26A or 320 at 40 CFR part 60, appendix A to this part for the concentration of hydrogen fluoride and hydrogen chloride.