40 CFR §63.7297
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
You must not discharge to the atmosphere any emissions from any HNR HRSG main stack at a new or existing HNR coke oven battery that exhibit emissions greater than the applicable limits in paragraphs (a) through (d) of this section.
- (a)Emissions of particulate matter from any HNR HRSG main stack at a new HNR coke oven battery that exceeds 8.8E-04 gr/dscf at 10 percent oxygen or any HNR HRSG main stack at an existing HNR coke oven battery that exceeds 0.0049 gr/dscf at 10 percent oxygen.
- (b)Emissions of mercury from any HNR HRSG main stack at a new HNR coke oven battery that exceeds 1.5E-06 gr/dscf at 10 percent oxygen or any HNR HRSG main stack at an existing HNR coke oven battery that exceeds 3.0E-06 gr/dscf at 10 percent oxygen.
- (c)Emissions of total acid gases from any HNR HRSG main stack at a new HNR coke oven battery that exceeds 0.0034 gr/dscf at 10 percent oxygen or any HNR HRSG main stack at an existing HNR coke oven battery that exceeds 0.049 gr/dscf at 10 percent oxygen.
- (d)Emissions of total PAHs from any HNR HRSG main stack at a new HNR coke oven battery that exceeds 4.7E-07 gr/dscf at 10 percent oxygen or any HRSG main stack at existing HNR coke oven battery that exceeds 4.8E-07 gr/dscf at 10 percent oxygen.