You must not discharge to the atmosphere any emissions from any HNR HRSG bypass/waste heat stack at a new or existing HNR coke oven battery that exhibit emissions greater than the applicable limits in paragraphs (a) through (e) of this section.
- (a)Emissions of particulate matter from any HNR HRSG bypass/waste heat stack at a new HNR coke oven battery that exceeds 0.022 gr/dscf at 10 percent oxygen or any HNR HRSG bypass/waste heat stack at an existing HNR coke battery that exceeds 0.032 gr/dscf at 10 percent oxygen.
- (b)Emissions of mercury from any HNR HRSG bypass/waste heat stack at a new HNR coke oven battery that exceeds 8.6E-06 gr/dscf at 10 percent oxygen or any HNR HRSG bypass/waste heat stack at an existing HNR coke oven battery that exceeds 1.2E-05 gr/dscf at 10 percent oxygen.
- (c)Emissions of total acid gases from any HNR HRSG bypass/waste heat stack at a new HNR coke oven battery that exceeds 0.12 gr/dscf at 10 percent oxygen or any HNR HRSG bypass/waste heat stack at an existing HNR coke battery that exceeds 0.095 gr/dscf at 10 percent oxygen.
- (d)Emissions of total PAHs from any HNR HRSG bypass/waste heat stack at a new or existing HNR coke oven battery that exceeds 2.7E-06 gr/dscf at 10 percent oxygen.
- (e)Emissions of formaldehyde from any HNR HRSG bypass/waste heat stack at a new HNR coke oven battery that exceeds 1.8E-05 gr/dscf at 10 percent oxygen or any HNR HRSG bypass/waste heat stack at an existing HNR coke oven battery that exceeds 0.0012 gr/dscf at 10 percent oxygen.