40 CFR §63.7898
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7895 applicable to your affected tanks by meeting the requirements in paragraphs (b) through (d) of this section.
- (b)You must demonstrate continuous compliance with the requirement to determine the applicable tank control level specified in § 63.7895(b) for each affected tank by meeting the requirements in paragraphs (b)(1) through (3) of this section.
- (1)Keeping records of the tank design capacity according to the requirements in § 63.1065(a).
- (2)For tanks subject to § 63.7886(b)(1)(ii) and not using Tank Level 2 controls, meeting the requirements in paragraphs (b)(2)(i) and (ii) of this section.
- (i)Keeping records of the maximum HAP vapor pressure determined according to the procedures in § 63.7944 for the remediation material placed in each affected tank.
- (ii)Performing a new determination of the maximum HAP vapor pressure whenever changes to the remediation material managed in the tank could potentially cause the maximum HAP vapor pressure to increase to a level that is equal to or greater than the maximum HAP vapor pressure for the tank design capacity specified in Table 2. You must keep records of each determination.
- (3)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (c)You must demonstrate continuous compliance for each tank determined to require Tank Level 1 controls by meeting the requirements in paragraphs (c)(1) through (5) of this section.
- (1)Operating and maintaining the fixed roof and closure devices according to the requirements in § 63.902(c), with the exceptions specified in § 63.7895(c)(1) and (2).
- (2)Visually inspecting the fixed roof and closure devices for defects at least annually according to the requirements in § 63.906(a).
- (3)Repairing defects according to the requirements in § 63.63.906(b).
- (4)Recording the information specified in § 63.907(a)(3) and (b).
- (5)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (d)You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a fixed roof with an internal floating roof according to § 63.7895(d)(1) by meeting the requirements in paragraphs (d)(1) through (5) of this section.
- (1)Operating and maintaining the internal floating roof according to the requirements in § 63.1063(b).
- (2)Visually inspecting the internal floating roof according to the requirements in § 63.1063(d)(1) and (2).
- (3)Repairing defects according to the requirements in § 63.1063(e).
- (4)Recording the information specified in § 63.1065(b) through (d).
- (5)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (e)You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using an external floating roof according to § 63.7895(d)(2) by meeting the requirements in paragraphs (e)(1) through (5) of this section.
- (1)Operating and maintaining the external floating roof according to the requirements in § 63.1063(b).
- (2)Visually inspecting the external floating roof according to the requirements in § 63.1063(d)(1) and inspecting the seals according to the requirements in § 63.1063(d)(2) and (3).
- (3)Repairing defects according to the requirements in § 63.1063(e).
- (4)Recording the information specified in § 63.1065(b) through (d).
- (5)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (f)You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a fixed roof vented to a control device according to § 63.7895(d)(3) by meeting the requirements in paragraphs (f)(1) through (6) of this section.
- (1)Operating and maintaining the fixed roof and closure devices according to the requirements in § 63.685(g).
- (2)Visually inspecting the fixed roof and closure devices for defects at least annually according to the requirements in § 63.695(b)(3)(i).
- (3)Repairing defects according to the requirements in § 63.695(b)(4).
- (4)Recording the information specified in § 63.696(e).
- (5)Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
- (6)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (g)You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and operated as a pressure tank according to § 63.7895(d)(4) by meeting the requirements in paragraphs (g)(1) through (3) of this section.
- (1)Operating and maintaining the pressure tank and closure devices according to the requirements in § 63.685(h).
- (2)Visually inspecting each pressurized tank and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.685(h), and recording the results of each inspection.
- (3)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (h)You must demonstrate continuous compliance for each tank determined to require Tank Level 2 controls and using a permanent total enclosure vented to an enclosed combustion device according to § 63.7895(d)(5) by meeting the requirements in paragraphs (h)(1) through (4) of this section.
- (1)Performing the verification procedure for the enclosure annually according to the requirements in § 63.685(i).
- (2)Recording the information specified in § 63.696(f).
- (3)Meeting each applicable requirement for demonstrating continuous compliance with the emissions limitations and work practice standards for a closed vent system and control device in § 63.7928.
- (4)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.