40 CFR §63.7913
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)You must demonstrate continuous compliance with the emissions limitations and work practice standards in § 63.7910 applicable to your affected separators by meeting the requirements in paragraphs (b) through (d) of this section as applicable to your surface impoundments.
- (b)You must demonstrate continuous compliance for each separator using a floating roof according to § 63.7910(b)(1) by meeting the requirements in paragraphs (b)(1) through (6) of this section.
- (1)Operating and maintaining the floating roof according to the requirements in § 63.1043(b).
- (2)Performing seal gap measurement inspections at least annually according to the requirements in § 63.1047(b)(1).
- (3)Visually inspecting the floating roof at least annually according to the requirements in § 63.1047(b)(2).
- (4)Repairing defects according to the requirements in § 63.1047(d).
- (5)Recording the information specified in § 63.1048(a) and (b).
- (6)Keeping records to document compliance with the requirements according to the requirements in § 63.7952.
- (c)You must demonstrate continuous compliance for each separator using a fixed roof vented through a closed vent system to a control device according to § 63.7910(b)(2) by meeting the requirements in paragraphs (c)(1) through (6) of this section.
- (1)Operating and maintaining the fixed roof and its closure devices according to the requirements in § 63.1042, with the exceptions specified in § 63.7911(c)(2).
- (2)Performing visual inspections of the fixed roof and its closure devices for defects at least annually according to the requirements in § 63.1047(a).
- (3)Repairing defects according to the requirements in § 63.1047(d).
- (4)Recording the information specified in § 63.1048(a).
- (5)Meeting each applicable requirement for demonstrating continuous compliance with the emission limitations and work practice standards for a closed vent system and control device in § 63.7928.
- (6)Keeping records to document compliance with the requirements of this subpart according to the requirements in § 63.7952.
- (d)You must demonstrate continuous compliance for each pressurized separator operated as a closed system according to § 63.7910(b)(3) by meeting the requirements in paragraphs (d)(1) and (2) of this section.
- (1)Operating the pressurized separator at all times according to the requirements in § 63.1045, with the exceptions specified in § 63.7910(b)(3).
- (2)Visually inspecting each pressurized tank and closure devices for defects at least annually to ensure they are operating according to the design requirements in § 63.1045(b), and recording the results of each inspection.