40 CFR §65.85
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Vapor tightness. For the purposes of demonstrating vapor tightness to determine compliance with § 65.84(c)(2), the following procedures and equipment shall be used:
- (1)The pressure test procedures specified in Method 27 of appendix A of 40 CFR part 60; and
- (2)A pressure measurement device that has a precision of ±2.5 millimeters of mercury (0.10 inch) or better and that is capable of measuring above the pressure at which the tank truck or railcar is to be tested for vapor tightness.
- (b)Engineering assessment. Engineering assessment to determine if a vent stream is halogenated or flow rate of a gas stream includes, but is not limited to, the following examples:
- (1)Previous test results, provided the tests are representative of current operating practices at the process unit.
- (2)Bench-scale or pilot-scale test data representative of the process under representative operating conditions.
- (3)Maximum flow rate or halogen emission rate specified or implied within a permit limit applicable to the process vent.
- (4)Design analysis based on accepted chemical engineering principles, measurable process parameters, or physical or chemical laws or properties.
- (5)All data, assumptions, and procedures used in the engineering assessment shall be documented.
- (c)Halogenated vent stream determination. In order to determine whether a vent stream is halogenated, the mass emission rate of halogen atoms contained in organic compounds shall be calculated as specified in paragraphs (c)(1) and (2) of this section.
- (1)The vent stream concentration of each organic compound containing halogen atoms (parts per million by volume by compound) shall be determined based on any of the following procedures:
- (i)Process knowledge that no halogen or hydrogen halides are present in the vent stream; or
- (ii)Applicable engineering assessment as specified in paragraph (b) of this section; or
- (iii)Concentration of organic compounds containing halogens measured by Method 18 of appendix A of 40 CFR part 60; or
- (iv)Any other method or data that have been validated according to the applicable procedures in Method 301 of appendix A of 40 CFR part 63.
- (2)Equation 85-1 of this section shall be used to calculate the mass emission rate of halogen atoms:
- (1)The vent stream concentration of each organic compound containing halogen atoms (parts per million by volume by compound) shall be determined based on any of the following procedures: