Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
  1. (a)Select applicable method(s) from the following list to extract PCBs and determine the PCB concentration from the standard wipe sample collection medium: SW-846 Method 3540C, Method 3550C, Method 3541, Method 3545A, Method 3546, or Method 8082A (all standards incorporated by reference in § 761.19). Modifications to the methods listed in this paragraph or alternative methods not listed may be used if validated under Subpart Q of this part or authorized in a § 761.61(c) approval.
  2. (b)Report all PCB sample concentrations in µg/100 cm 2 (16 square inches) of surface sampled. If sampling an area smaller than 100 cm 2, report converted sample concentrations in accordance with § 761.243(b).