40 CFR §761.395
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Decontaminate the following prepared sample surfaces using the selected testing parameters and experimental conditions. Take a standard wipe sample of the decontaminated surface.
- (b)
- (1)Select applicable method(s) from the following list to extract PCBs and determine the PCB concentration from the standard wipe sample collection medium: SW-846 Method 3540C, Method 3550C, Method 3541, Method 3545A, Method 3546, or Method 8082A (all standards incorporated by reference in § 761.19). Modifications to the methods listed in this paragraph or alternative methods not listed may be used if validated under subpart Q of this part.
- (2)Report all validation study surface sample concentrations on the basis of micrograms of PCBs per 100 cm 2 of surface sampled.
- (c)Following completion of the validation study, measurements from the contaminated surfaces must have an arithmetic mean of ≤10 µg/100 cm 2. If the arithmetic mean is >10 µg/100 cm 2, then the validation study failed and the solvent may not be used for decontamination under § 761.79(d)(4) according to the parameters tested.