40 CFR §98.496
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
In addition to the reporting requirements of § 98.3(c), you must report the information specified in paragraphs (a) through (i) of this section for each coke calcining unit.
- (a)The unit ID number (if applicable).
- (b)Maximum rated throughput of the unit, in metric tons coke calcined/stream day.
- (c)The calculated CO2, CH4, and N2O annual process emissions, expressed in metric tons of each pollutant emitted.
- (d)A description of the method used to calculate the CO2 emissions for each unit (e.g., CEMS or equation 1 to § 98.493(b)(2)).
- (e)Annual mass of green coke fed to the coke calcining unit from facility records (metric tons/year).
- (f)Annual mass of marketable petroleum coke produced by the coke calcining unit from facility records (metric tons/year).
- (g)Annual mass of petroleum coke dust removed from the process through the dust collection system of the coke calcining unit from facility records (metric tons/year) and an indication of whether coke dust is recycled to the unit (e.g., all dust is recycled, a portion of the dust is recycled, or none of the dust is recycled).
- (h)Annual average mass fraction carbon content of green coke fed to the coke calcining unit from facility measurement data (metric tons C per metric ton green coke).
- (i)Annual average mass fraction carbon content of marketable petroleum coke produced by the coke calcining unit from facility measurement data (metric tons C per metric ton petroleum coke).