StacksVerified U.S. regulatory reference

40 CFR Part 63, Table 1

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
For the following existing sources . . .You must meet the emission limits for the specified pollutant . . .
Total fluoridesTotal particulate | Mercury
Wet-Process Phosphoric Acid Line0.020 lb/ton of equivalent P2 O5 feed | |
Superphosphoric Acid Process Line c0.010 lb/ton of equivalent P2 O5 feed | |
Superphosphoric Acid Process Line with a Submerged Combustion Process0.20 lb/ton of equivalent P2 O5 feed | |
Phosphate Rock Dryer| 0.2150 lb/ton of phosphate rock feed |
Phosphate Rock Calciner9.0E-04 lb/ton of rock feed d | 0.181 g/dscm | 0.23 mg/dscm corrected to 3-percent oxygen e

a The existing source compliance data is June 10, 2002, except as noted.

b During periods of startup and shutdown, for emission limits stated in terms of pounds of pollutant per ton of feed, you are subject to the work practice standards specified in § 63.602(f).

c Beginning on August 19, 2018, you must include oxidation reactors in superphosphoric acid process lines when determining compliance with the total fluorides limit.

d Compliance date is August 19, 2015.

e Compliance date November 3, 2020.

[85 FR 69512, Nov. 3, 2020]