40 CFR Part 60, Table 2

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov
For the following municipal waste combustion unitsYou must meet the followingcarbon monoxide limits aUsing the following averaging times b
1. Fluidized-bed100 parts per million by dry volume4-hour.
2. Fluidized bed, mixed fuel, (wood/refuse-derived fuel)200 parts per million by dry volume24-hour. c
3. Mass burn rotary refractory100 parts per million by dry volume4-hour.
4. Mass burn rotary waterwall100 parts per million by dry volume24-hour.
5. Mass burn waterwall and refractory100 parts per million by dry volume4-hour.
6. Mixed fuel-fired (pulverized coal/refuse-derived fuel)150 parts per million by dry volume4-hour.
7. Modular starved-air and excess air50 parts per million by dry volume4-hour.
8. Spreader stoker, mixed fuel-fired (coal/refuse-derived fuel)150 parts per million by dry volume24-hour daily.
9. Stoker, refuse-derived fuel150 parts per million by dry volume24-hour daily.

a All limits (except for opacity) are measured at 7 percent oxygen. Compliance is determined by continuous emission monitoring systems.

b Block averages, arithmetic mean. See § 60.1465 for definitions.

c 24-hour block average, geometric mean. See § 60.1465 for definitions.