StacksVerified U.S. federal law reference

40 CFR Part 63, Table 27 — Summary of Internal Floating Deck Fitting Loss Factors (KF) and Typical Number of Fittings (NF)

Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
Deck fitting typeDeck fitting loss factor (KF) aTypical number of fittings (NF)
Access hatch| 1
Bolted cover, gasketed1.6
Unbolted cover, gasketed11
Unbolted cover, ungasketedb 25
Automatic gauge float well| 1
Bolted cover, gasketed5.1
Unbolted cover, gasketed15
Unbolted cover, ungasketedb 28
Column well| (see Table 24).
Builtup column-sliding cover, gasketed33
Builtup column-sliding cover, ungasketedb 4710
Pipe column-flexible fabric sleeve seal19
Pipe column-sliding cover, gasketed32
Pipe column-sliding cover, ungasketed
Ladder well| 1
Sliding cover, gasketed56
Sliding cover, ungasketedb 76
Roof leg or hanger well| (5 + D/10 + D 2/600) c.
Adjustableb 7.9
Fixed0
Sample pipe or well| 1
Slotted pipe-sliding cover, gasketed44
Slotted pipe-sliding cover, ungasketed57
Sample well-slit fabric seal, 10 percent open areab 12
Stub drain, 1-in diameter d1.2(D 2/125) c.
Vacuum breaker| 1
Weighted mechanical actuation, gasketedb 0.7
Weighted mechanical actuation, ungasketed0.9

a Units for KF are pound-moles per year.

b If no specific information is available, this value can be assumed to represent the most common/typical deck fittings currently used.

c D = Tank diameter (feet).

d Not used on welded contact internal floating decks.