For the operating parameter applicable to you, as specified in Table 3 . . .You must establish the following operating limit during your performance test . . .And you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . .
Data measurementData recordingData averagingperiod forcompliance

Absorbers (Wet Scrubbers)

Influent liquid flowMinimum inlet liquid flowContinuousEvery 15 minutesDaily.
Influent liquid flow rate and gas stream flow rateMinimum influent liquid-to-gas ratio aContinuousEvery 15 minutesDaily.
For the operating parameter applicable to you, as specified in Table 3You must establish the following operating limitAnd you must monitor, record, and demonstrate continuous compliance using these minimum frequencies . . .
Data measurementData recordingData averagingperiod forcompliance.
Pressure dropPressure drop rangeContinuousEvery 15 minutesDaily.

Sorbent Injection

Sorbent injection rateMinimum injection rateContinuousEvery 15 minutesDaily.
Sorbent injection carrier gas flow rateMinimum carrier gas flow rateContinuousEvery 15 minutesDaily.

Fabric Filters

Alarm time | Maximum alarm time is not established on a site-specific basis but is specified in § 63.605(f)(9) | Continuous | Each date and time of alarm start and stop | Maximum alarm time specified in § 63.605(f)(9).

Wet Electrostatic Precipitator

Secondary voltage | Secondary voltage range | Continuous | Every 15 minutes | Daily.

[82 FR 45201, Sept. 28, 2017]