Particle Aerodynamic Diameter (µm)Test SamplerIdeal Sampler
Fractional Sampling EffectivenessInterval Mass Concentration (µg/m3)Estimated Mass Concentration Measurement (µg/m3) | Fractional Sampling Effectiveness | Interval Mass Concentration (µg/m3) | Estimated Mass Concentration Measurement (µg/m3)
(1)(2)(3) | (4) | (5) | (6) | (7)
<0.500118.868 | | 1 | 18.868 | 18.868
0.625| 13.412| 0.999 | 13.412 | 13.399
0.75| 8.014| 0.998 | 8.014 | 7.998
0.875| 6.984| 0.997 | 6.984 | 6.963
1| 5.954| 0.995 | 5.954 | 5.924
1.125| 5.015| 0.991 | 5.015 | 4.97
1.25| 4.197| 0.987 | 4.197 | 4.142
1.375| 3.503| 0.98 | 3.503 | 3.433
1.5| 2.921| 0.969 | 2.921 | 2.83
1.675| 2.438| 0.954 | 2.438 | 2.326
1.75| 2.039| 0.932 | 2.039 | 1.9
1.875| 1.709| 0.899 | 1.709 | 1.536
2| 1.437| 0.854 | 1.437 | 1.227
2.125| 1.212| 0.791 | 1.212 | 0.959
2.25| 1.026| 0.707 | 1.026 | 0.725
2.375| 0.873| 0.602 | 0.873 | 0.526
2.5| 0.745| 0.48 | 0.745 | 0.358
2.625| 0.638| 0.351 | 0.638 | 0.224
2.75| 0.55| 0.23 | 0.55 | 0.127
2.875| 0.476| 0.133 | 0.476 | 0.063
3| 0.414| 0.067 | 0.414 | 0.028
3.125| 0.362| 0.03 | 0.362 | 0.011
3.25| 0.319| 0.012 | 0.319 | 0.004
3.375| 0.282| 0.004 | 0.282 | 0.001
3.5| 0.252| 0.001 | 0.252 | 0
3.625| 0.226| 0 | 0.226 | 0
3.75| 0.204| 0 | 0.204 | 0
3.875| 0.185| 0 | 0.185 | 0
4| 0.17| 0 | 0.17 | 0
4.125| 0.157| 0 | 0.157 | 0
4.25| 0.146| 0 | 0.146 | 0
4.375| 0.136| 0 | 0.136 | 0
4.5| 0.129| 0 | 0.129 | 0
4.625| 0.122| 0 | 0.122 | 0
4.75| 0.117| 0 | 0.117 | 0
4.875| 0.112| 0 | 0.112 | 0
5| 0.108| 0 | 0.108 | 0
5.125| 0.105| 0 | 0.105 | 0
5.25| 0.102| 0 | 0.102 | 0
5.375| 0.1| 0 | 0.1 | 0
5.5| 0.098| 0 | 0.098 | 0
5.625| 0.097| 0 | 0.097 | 0
5.75| 0.096| 0 | 0.096 | 0
Csam(exp)= | | | Cideal(exp)= | 78.539