42 CFR §84.104
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Each apparatus will be tested for tightness by persons wearing it in an atmosphere of 1,000 p.p.m. isoamyl acetate.
- (b)Six persons will each wear the apparatus in the test concentrations specified in paragraph (a) of this section for 2 minutes and none shall detect the odor or taste of the test vapor.