42 CFR §84.149
Verified against eCFR.gov as of June 20, 2026View official text on eCFR.gov ↗
- (a)Respirators tested under this section shall be approved only when used to supply respirable air at the pressures and quantities required.
- (b)The manufacturer shall specify the range of air pressure at the point of attachment of the air-supply hose to the air-supply system, and the range of hose length for the respirator. For example, he might specify that the respirator be used with compressed air at pressures ranging from 280-550 kN/m. 2 (40 to 80 pounds per square inch) with from 6 to 76 m. (15 to 250 feet) of air-supply hose.
- (c)The specified air pressure at the point of attachment of the hose to the air-supply system shall not exceed 863 kN/m. 2 (125 pounds per square inch gage).
- (d)
- (1)Where the pressure in the air-supply system exceeds 863 kN/m. 2 (125 pounds per square inch gage), the respirator shall be equipped with a pressure-release mechanism that will prevent the pressure at the point of attachment of the hose to the air-supply system from exceeding 863 kN/m. 2 (125 pounds per square inch gage).
- (2)The pressure-release mechanism shall be set to operate at a pressure not more than 20 percent above the manufacturer's highest specified pressure. For example, if the highest specified pressure is 863 kN/m. 2 (125 pounds per square inch), the pressure-release mechanism would be set to operate at a maximum of 1,035 kN/m. 2 (150 pounds per square inch).